GUIDE TO INSTALLATION AND OPERATION
60 | Kaleido-Solo
5.9 General - GPI
See section 2.3 for GPI connections.
GPI Status
Active:
Shows if the GPI inputs and/or output are considered active (close).
Inactive:
Shows if the GPI inputs and/or output are considered inactive (open).
GPI Input Action
You can assign an action from a GPI input. This action will occur when the associated GPI is detected as active.
Here are the possibilities:
No Action:
Nothing.
Load User Preset 1 to 5:
Load a previously saved associated preset (see section 5.7).
Reset Loudness:
Reset loudness measurement (see section 5.4.7).
Run/Pause Loudness:
Toggle between run and pause loudness measurement base on the GPI input level
(Inactive = Run, Active = Pause) (see section 5.4.7).
Tally Program:
Activate the left most tally (see section 5.5.8).